Features:
Current Sensing type
Available for 5 to 20 HP
Economical
ABS Body
Motor ON Indication
Wire passing type design
Dry Relay Contacts
Compatible with all 3 Phase Starters
Rating:
5 to 20HP
3 Phase motors need the power supply to be present in all the 3 supply phases. Failing of any one of the phases is termed as single phasing. During single phasing, the motors draw more current than the rated value which results in burning of the motor coils.
Single Phase Preventor is a product which provides a solution to this problem by sensing the single phase condition and instantaneously turning OFF the power supply to the motor. Single Phase preventors are mandatorily used in the majority of 3 Phase motor starters.
There are 9 products.
Features:
Current Sensing type
Available for 5 to 20 HP
Economical
ABS Body
Motor ON Indication
Wire passing type design
Dry Relay Contacts
Compatible with all 3 Phase Starters
5 to 20HP
Features:
Current Sensing type
Available in 5 to 12.5 HP
Heavy Duty
Metal Body
Motor ON Indication
Connector type design
Dry Relay Contacts
Compatible with all 3 Phase Starters
5 to 12.5HP
Features:
Current Sensing type
Available in 5 to 12.5 HP
Heavy Duty
Metal Body
Motor ON Indication
Connector type design
Dry Relay Contacts
Compatible with all 3 Phase Starters
5 to 12.5HP
Features:
Current Sensing type
Available for 5 to 12.5 HP
Metal Body
Motor ON Indication
Connector type design
Dry Relay Contacts
Compatible with all 3 Phase Starters
5 to 7.5HP
Features:
Current Sensing type
Available in 1 to 3HP and 3 to 6HP variants
Metal Body
Motor ON Indication
Connector type design
Dry Relay Contacts
Compatible with all 3 Phase Starters
Available in 2 variants
1HP to 3HP
3HP to 6HP
Features:
Voltage Sensing type
ABS Body
Compact design
Preventor ON Indication
Dry Relay Contacts
Compatible with all 3 Phase Starters
Supply sequence reverse blink indication
1HP to 20HP
Features:
Voltage Sensing type
ABS Body
Auto Start Unit
Adjustable Power On Delay
Single Phase Protection
Preventor ON Indication
Auto Start ON Indication
Dry Relay Contacts for both Auto Start and Preventor
Compact design
Compatible with all 3 Phase Starters
Suitable for DOL and Star Delta Starters
Supply sequence reverse blink indication
1HP to 25HP
Features:
Voltage Sensing type
ABS Body
Auto Start Unit
Adjustable Star to Delta Change Over Time
Single Phase Protection
Preventor ON Indication
Auto Start ON Indication
Dry Relay Contacts for both Auto Start and Preventor
Compact design
Compatible with all 3 Phase Starters
Suitable for DOL and Star Delta Starters
Supply sequence reverse blink indication
1HP to 25HP
Features:
Voltage Sensing type
ABS Body
Auto Start Unit
Single Phase Protection
Preventor ON Indication
Auto Start ON Indication
Dry Relay Contacts for both Auto Start and Preventor
Compact design
Compatible with all 3 Phase Starters
Suitable for DOL and Star Delta Starters
Supply sequence reverse blink indication
1HP to 20HP